Sinho
SinhoLoad the app
SinhoUniversity

Spring

Price reaches below the range’s floor, firing when a qualifying close reclaims that edge.

At a glance#

Direction
Bullish
Fires
At the candle's close
Timeframes
All nine, 1m to 1d
Mirror
Upthrust

Follow it on Sinho#

How does it fire?#

What it tells you
A move below the trading range’s floor has failed to hold. Sinho records the return across that boundary.
When Sinho fires
At the close reclaiming the range’s floor, either on the sweep candle or within the following three candles.

Anatomy#

Three parts, in the order they happen. Up candles are hollow, down candles filled.

1The range2The sweep3The close
  1. 1The range

    The range has fixed edges and has matured through age and touches on both sides.

  2. 2The sweep

    Price reaches below the floor. The depth is measured against ATR.

  3. 3The close

    The sweep candle closes in its upper half and back across the floor in this example. Sinho fires here.

What Sinho checks#

The main rules, in plain words.

  • A fixed trading range

    A sustained sideways move establishes the range’s ceiling and floor.

  • An established range

    Price has spent time in the range and visited both its ceiling and its floor.

  • A one-candle sweep

    Price sweeps below the floor, then returns inside on the same candle.

  • A rejection close

    The returning candle closes away from its low, showing rejection below the range.

  • A later reclaim

    A close below the floor can also qualify if price promptly closes back inside the range.

  • The close

    Sinho fires when the qualifying reclaim candle closes at or above the range’s floor. The one-candle form also needs its rejection close.

Zones and the Level Book#

When a Spring fires on 5m or higher, Sinho adds the area at the range floor to the Level Book. Levels that sit close together form Zones: areas of confluence where multiple support and resistance levels meet. Signals, levels and Zones all feed Sinho's Setups.

1The saved area2A Zone3Zone Approach4Zone Hit
  1. 1The saved area

    Sinho saves the area between the firing candle's low and the range floor as support on that chart.

  2. 2A Zone

    A watched level within a quarter of a typical 15m range joins it. A Zone fires with 2 independent levels, or 1 strong one.

  3. 3Zone Approach

    When price is an estimated 2 to 5 minutes away, Sinho can fire one Zone Approach for the whole Zone.

  4. 4Zone Hit

    Sinho fires a Zone Hit on the trade that reaches its near edge, scored 0 to 100 against this exchange's last 7 days.

Recent Spring Signals#

Every Spring Sinho fires, on every exchange and timeframe, is in the Feed as it happens.

Recent Spring Zone Hits and Approaches#

Zone Hits and Approaches at Zones that hold a Spring level are in the Feed's Zones tab as they happen.

Questions traders ask#

Must the candle’s body point in the Signal’s direction?

No. The candle’s open is not part of this rule. A one-candle sweep must meet the close-position rule; a later reclaim need not.

Does volume have to be high or low?

Neither. This Signal is defined by the established range, the sweep’s depth and the reclaim. It has no volume condition.

Is the sweep’s ATR frozen when the move begins?

No. The depth is judged against the ATR available before the reclaim candle. In a multi-candle excursion, that can differ from ATR when the sweep began.

Can the same range produce another one?

Yes. A reclaim keeps the range active. A later qualifying sweep and return can produce another Signal.

Which part becomes a level?

On 5m and up, the area between the firing candle’s low and the range’s floor is saved. For a later reclaim, that uses the reclaim candle’s low, not an earlier candle’s extreme.

Key takeaways#

  1. 1

    Spring needs an established range and a return across its floor.

  2. 2

    A one-candle sweep needs 0.30–1.5× ATR penetration and a close in the rejection half.

  3. 3

    A later reclaim has three candles to return; its deepest sweep must be 0.10–1.5× ATR.

  4. 4

    On 5m and up, the firing candle’s low-to-floor area is saved in the Sinho LevelBook to generate Zones and Setups from.

Words on this page#

Candle range
The distance from a candle's low to its high, including both wicks.
At the close
Sinho checks the rule when the candle closes, and fires then.
ATR
Average true range: how far a bar usually travels, counting gaps between bars.
Wilder ATR
A smoothed average of true range. Sinho uses the prior candle’s value, before the candle being evaluated changes it.

Rules as of 25 Oct 2026. Sinho shows Signals, not advice.