Liquidation Flush
A burst of forced closing meets a rejection candle, firing when its long wick and closing price reclaim the Cascade’s reference.
At a glance#
- Direction
- Either way
- Fires
- At the candle's close
- Timeframes
- 1m
Follow it on Sinho#
How does it fire?#
- What it tells you
- A long-liquidation burst rejects upward, or a short-liquidation burst rejects downward. Sinho records the reversal away from that burst.
- When Sinho fires
- At the first qualifying 1m candle’s close, in the Cascade’s own minute or one of the next 3 minutes.
Anatomy#
Three parts, in the order they happen. Up candles are hollow, down candles filled.
- 1Cascade
A published Cascade supplies its dollar-weighted liquidation price as the reference.
- 2Wick
The rejection-side wick spans at least half of the candle’s entire high-to-low range.
- 3Close
After long liquidations, the close reaches or exceeds the reference. Sinho fires here; short liquidations mirror it.
What Sinho checks#
The main rules, in plain words.
- A Cascade comes first
A published Liquidation Cascade must already exist. Its counted reports’ dollar-weighted average price supplies the reference.
- A prompt response
The rejection appears during or soon after the Cascade.
- The wick reaches the reference
After long liquidations, the candle’s low reaches or crosses below the reference. After short liquidations, its high reaches or crosses above it.
- A pronounced wick
A long lower wick follows long liquidations; a long upper wick follows short liquidations. The wick shows price pulling back from the forced move.
- A close back across
After long liquidations the close is at or above the Cascade reference. After short liquidations it is at or below. Equality counts.
- The close
Sinho fires when the first qualifying candle with a rejecting wick closes back across the reference soon after the Cascade.
Zones and the Level Book#
When a Liquidation Flush fires, Sinho adds the candle's wick to the Level Book. Levels that sit close together form Zones: areas of confluence where multiple support and resistance levels meet. Signals, levels and Zones all feed Sinho's Setups.
- 1Wick saved
to Level Book
Sinho saves the flush candle's low for longs or high for shorts as a 15m support or resistance level.
- 2A Zone
A watched level within a quarter of a typical 15m range joins it. A Zone fires with 2 independent levels, or 1 strong one.
- 3Zone Approach
When price is an estimated 2 to 5 minutes away, Sinho can fire one Zone Approach for the whole Zone.
- 4Zone Hit
Sinho fires a Zone Hit on the trade that reaches its near edge, scored 0 to 100 against this exchange's last 7 days.
Recent Liquidation Flush Signals#
Every Liquidation Flush Sinho fires, on every exchange and timeframe, is in the Feed as it happens.
Recent Liquidation Flush Zone Hits and Approaches#
Zone Hits and Approaches at Zones that hold a Liquidation Flush level are in the Feed's Zones tab as they happen.
Questions traders ask#
How is the wick measured?
The lower wick runs from the low to the lower of that candle’s open and close. The upper wick runs from the higher of its open and close to its high.
Does the body need a particular color?
No. The wick and reference-crossing rules decide it. A qualifying bullish Flush can have a downward body, and the bearish mirror can have an upward body.
Can the Cascade’s own candle fire the Flush?
Yes. Once that minute closes, it is the first candle checked. Sinho does not require the rejection to start on the next minute.
Does every Cascade produce a Flush?
No. Without a qualifying candle in that window, the Cascade remains a burst without this separate rejection Signal.
Which level does it save?
The rejection candle’s low after long liquidations, or its high after short liquidations. Sinho saves that wick extreme as a 15m LevelBook level, although the Flush is a 1m Signal.
Key takeaways#
- 1
A Liquidation Flush requires a published Cascade and a qualifying 1m rejection candle.
- 2
The rejection wick spans at least half the candle’s full range.
- 3
The first qualifying close in the Cascade’s minute or the next 3 minutes fires once.
- 4
The wick extreme, as a 15m level, is saved in the Sinho LevelBook to generate Zones and Setups from.
Words on this page#
- Body
- The part of a candle between its open and close. Outlined here when it closes up, filled when it closes down.
- Candle range
- The distance from a candle's low to its high, including both wicks.
- At the close
- Sinho checks the rule when the candle closes, and fires then.
